ASME Certified Heat Exchangers HVS STABILIZER FEED EXCHANGER For Hydrocracking Unit
YUHONG specializes in the engineering and fabrication of mission-critical heat transfer equipment for the global oil and gas industry. We provide high-standard solutions for major refineries, such as the REPLAN facility in Brazil, ensuring compliance with rigorous international standards (ASME/ASTM) and specific client requirements like those of Petrobras. Our expertise lies in handling complex metallurgy for high-temperature and high-pressure hydrotreating environments.
Bill of Materials (BOM) for Tube Bundle
| Item No. |
Description |
Dimensions (mm) |
Material Standard |
| 41 |
"U" TUBES |
ϕ25.4×2.11 THK (MW)×2135 STR.LG. |
SA 213 Gr.T11 |
| 42 |
SEALING RODS |
ϕ30×1130 LG. |
SA 36 |
| 43 |
SLIDING STRIPS |
PL.25×16 THK×1999 LG. |
SA 387 Gr.11 Cl.2 |
| 44 |
SEALING STRIPS |
PL.55×10 THK×1130 LG. |
SA 387 Gr.11 Cl.2 |
| 45 |
TIE RODS |
ϕ1/2"−UNC×2030 LG. |
SA 193 Gr.B7 |
| 46 |
HEX. NUTS |
ϕ1/2"−UNC(H=D) |
SA 194 Gr.2H |
| 47 |
SPACERS |
ϕ25.4×2.11 THK |
SA 213 Gr.T11 |
| 48 |
ODD BAFFLES |
O.D.985.2×10 THK |
SA 387 Gr.11 Cl.2 |
| 49 |
EVEN BAFFLES |
O.D.985.2×10 THK |
SA 387 Gr.11 Cl.2 |
| 50 |
SUPP. BAFFLE |
O.D.985.2×10 THK |
SA 387 Gr.11 Cl.2 |
| 51 |
IMPINGEMENT PL. |
10 THK |
SA 387 Gr.11 Cl.2 |
| 52 |
SLIDING RAILS |
PL.50×6 THK×2000 LG. |
SA 240-304L
|
U-Tube Arrangement and Dimensions
| ROW No. |
Quantity (Q.TY) |
Radius R (mm) |
Development Length (mm) |
Thickness (THK) |
| 1 |
29 |
38.1 |
4390 |
2.11 MW |
| 2 |
29 |
69.85 |
4489 |
2.11 MW |
| 3 |
29 |
101.6 |
4589 |
2.11 MW |
| 4 |
29 |
133.35 |
4689 |
2.11 MW |
| 5 |
27 |
165.1 |
4789 |
2.11 MW |
| 6 |
27 |
196.85 |
4888 |
2.11 MW |
| 7 |
27 |
228.6 |
4988 |
2.11 MW |
| 8 |
25 |
260.35 |
5088 |
2.11 MW |
| 9 |
23 |
292.1 |
5188 |
2.11 MW |
| 10 |
23 |
323.85 |
5287 |
2.11 MW |
| 11 |
19 |
355.6 |
5387 |
2.11 MW |
| 12 |
17 |
387.35 |
5487 |
2.11 MW |
| 13 |
11 |
419.1 |
5587 |
2.11 MW |
Product Application & Use Cases
The HEAT EXCHANGERS is a specialized U-tube heat exchanger designed for the Naphtha Coker Hydrotreating Unit.
Primary Function: Preheating the feed for the Stabilizer Column by recovering heat from downstream process streams.
Operational Context: Specifically engineered for the treatment of unstable coker naphtha streams to remove sulfur and nitrogen contaminants.
Industry Application: Essential for refinery gasoline units focused on improving fuel quality and meeting environmental standards.