ASME Section VIII Div.1 Stainless Steel Shell & Tube Heat Exchanger for Chemical & Petrochemical Process Cooling

Place of Origin: CHINA
Brand Name: YUHONG
Certification: ASME VIII, U STAMP , PED, API , ABS, LR, DNV, GL , BV, KR, TS, CCS
Model Number: HEAT EXCHANGER
Minimum Order Quantity: 1 SET
Price: Negotiable
Packaging Details: Pallet
Delivery Time: Depends on order quantity
Payment Terms: T/T,L/C
Supply Ability: 50 SETS / MONTHS
Inquiry Now
Get A Quote
Specifications
Highlight Features

ASME stainless steel heat exchanger

,

shell & tube heat exchanger

,

TEMA heat exchanger for process cooling

Product Description
Product Overview

Yuhong Group's shell and tube heat exchanger is a code-stamped pressure vessel built to ASME Section VIII Division 1 with optional ASME "U" Stamp and TEMA (C/T/R class) configurations. It transfers heat between two fluids—one through the tube side, one through the shell side—without direct contact, serving heating, cooling, condensation, or evaporation duties in chemical, petrochemical, and power generation circuits.

The unit addresses the core operational problem of thermal duty reliability under corrosive or high-temperature media. The differentiation lies in verifiable construction: every unit receives 100% hydrostatic pressure testing before shipment, and the tube-to-tubesheet joint is available in welded, expanded, or strength-welded-plus-light-expanded configurations to suit cyclic service. The visible nitrogen-filled preservation (labeled on the shell) protects internal surfaces during storage and ocean transit prior to commissioning.


Operating Parameters & Material Comparison
Key Operating Parameters
Parameter Standard Range Yuhong Customization
Design Pressure 0.1 – 60 MPa High-pressure reinforced design available
Design Temperature -196°C to +600°C Cryogenic, medium, and high-temperature systems
Heat Transfer Area 1 – 3,000 m² Sized to thermal load and installation footprint
Tube Diameter Φ19×2, Φ25×2.5, Φ38×3 mm Optimized for flow velocity and fouling allowance
HS Code 8419.50 Heat exchange units, industrial type
Material Options
Material Option Shell Side Tube Side Primary Selection Driver
Carbon Steel Q345R / SA516 Gr.70 SA179 / SA192 Clean, non-corrosive media; cost-sensitive duty
Stainless Steel 304 / 316L 304 / 316L Moderate corrosivity; food-grade or chemical streams
Duplex / Super Duplex 2205 / 2507 2205 / 2507 Chloride-bearing water; stress corrosion cracking resistance
Titanium / Nickel Alloy Gr.2 / C276 Gr.2 / C276 Severe corrosive service; seawater or acidic environments
For heavy-fouling shell-side media, TEMA "C" rear head (removable bundle) is specified; for large temperature differentials, TEMA "U" (U-tube) accommodates free thermal expansion. Fixed tubesheet (TEMA "L" / BEM) remains the economical choice for clean services with low ΔT.

Application & Compliance: Refinery Process Cooling

In a refinery or petrochemical train, this exchanger is deployed as a post-reactor process cooler. The tube side carries cooling water; the shell side receives hot hydrocarbon or chemical process fluid. The ASME Section VIII Div.1 design basis ensures the pressure boundary is calculated for the specified MAWP and hydrotested at 1.3× design pressure, directly mitigating the risk of shell-side leakage into the cooling circuit. The welded tube-to-tubesheet joint (or strength-weld-plus-expansion) provides a documented barrier against cross-contamination between the two fluid streams—a recurring failure point in gasketed-only designs. For units requiring frequent mechanical cleaning, the TEMA "C" removable bundle configuration allows tube-side access without cutting shell nozzles.


Standards & Certifications
  • Design & Fabrication: ASME Boiler & Pressure Vessel Code, Section VIII, Division 1; ASME "U" Stamp available.
  • Mechanical Standard: TEMA Class C, T, or R as specified.
  • Testing: 100% hydrostatic test at 1.3× design pressure; tube-to-tubesheet joint integrity verified per project specification.
  • Documentation: Manufacturer's Data Report (Form U-1A where U-Stamp applies), material certificates, and NDE records.

FAQ: Procurement & Technical Clarifications
Q1: What is the typical lead time and MOQ for an ASME-stamped unit?

MOQ is 1 set for project-specific configurations. Standard lead time ranges from 30 to 100 days after drawing approval, depending on material availability and whether ASME "U" Stamp third-party inspection is required.

Q2: How is FOB pricing structured for a shell and tube exchanger?

FOB pricing is quotation-based per project, factoring design pressure, material grade, tube count, and certification scope. A budgetary FOB range for ASME/TEMA units is typically USD 10,000 – 500,000 depending on heat transfer area and alloy selection. Final FOB terms are confirmed after HTRI thermal sizing and mechanical drawing review.

Q3: What causes tube-side fouling and how does the design address it?

Fouling reduces the overall U-value; a 15–25% decline from baseline is a commonly used inspection trigger in field practice. This exchanger mitigates fouling through selectable tube pitch (increased pitch for fouling streams), removable bundle options for mechanical cleaning, and nitrogen-filled preservation to inhibit corrosion product buildup during idle periods.


Packaging & Shipping

Each unit is prepared for sea-worthy export: internal surfaces receive anti-corrosion treatment, nozzles are capped, and the assembly is secured in a plywood or iron case with the tube bundle protected by plastic end caps. For European destinations, wooden packaging is fumigated per ISPM 15. Skid-mounted or unassembled configurations are available for space-constrained containers.


Request a Technical Quotation

To receive a project-specific proposal with MOQ, FOB terms, and estimated Lead Time, submit the following via the inquiry form on our website:

  1. Design pressure and temperature (shell side / tube side).
  2. Fluid names and flow rates.
  3. Required heat transfer duty (kW) or target outlet temperatures.
  4. TEMA type preference (if known) and material constraints.
  5. Destination port for FOB quotation.
ASME Section VIII Div.1 stainless steel shell and tube heat exchanger with TEMA configuration for chemical and petrochemical process cooling

ASME Section VIII Div.1 shell and tube heat exchanger — TEMA configuration for refinery and petrochemical process cooling.

Overall Rating
4.3
Based On Recent Reviews
Rating Snapshot
5
33%
4
67%
3
0
2
0
1
0
All Reviews
John from United States
Dec 9.2025
We purchased this heat exchanger for a critical amine service in our Texas plant. The ASME VIII-1 stamp gave us the confidence we needed for regulatory compliance. Upon arrival, our third-party inspector did a thorough check—he was impressed by the weld quality and the precise thickness of the SA516 Gr485 shell. It's been running continuously for six months now with zero issues. The documentation package (including material test reports and NDT reports) was complete and well-organized. Definitely a supplier we'll consider for future expansions.
N
Nguyen Van Nam from Vietnam
Oct 18.2025
Fast delivery and easy install. We scaled up our fertilizer plant and needed a quick turnaround. The lead time was better than expected. Flange alignments were perfect, which made the onsite installation very straightforward.
Y
Yerlan Smagulov from Kazakhstan
Jul 5.2025
This unit is handling our crude oil pre-heating in Atyrau perfectly. The ASME U-stamp made our safety audit a breeze.
Related Products
Send An Inquiry