API 661 Air Cooler Steel Structure Installation Drawing for Refinery Projects

Place of Origin: CHINA
Brand Name: YUHONG
Certification: API 661, ASME, U STAMP, PED, API, ABS, LR, DNV, GL , BV, KR, TS, CCS
Model Number: AIR COOLER
Minimum Order Quantity: 1 SET
Price: Negotiable
Packaging Details: Pallet
Delivery Time: Depends on order quantity
Payment Terms: T/T,L/C
Supply Ability: 50 SETS / MONTHS
Inquiry Now
Get A Quote
Specifications
Highlight Features

API 661 air cooler drawing

,

steel structure installation drawing

,

refinery air cooled heat exchanger

Product Description
1. Product Overview

YUHONG GROUP provides API 661 air cooler for industrial air-cooled heat exchanger projects. The drawing package illustrates the structural arrangement, component positioning and erection sequence of the supporting steel framework, providing a clear reference for equipment installation and on-site assembly.

For refinery and petrochemical projects, accurate structural installation information is essential for coordinating equipment positioning, steelwork fabrication and field erection. A well-organized erection drawing helps contractors identify component locations, understand structural connections and coordinate installation activities before equipment commissioning.

YUHONG GROUP offers project-oriented engineering and manufacturing solutions for air-cooled heat exchangers, tube bundles, finned tubes and associated equipment. Structural arrangements can be developed according to approved project drawings, equipment dimensions and purchaser specifications.

2. Technical Parameters & Material Options
Item Technical Description
Equipment API 661 Air Cooler
Drawing Type Installation Layout / Steel Structure Erection Drawing
Main Structure Columns, beams, cross members and bracing
Access Components Platforms, walkways, handrails and ladders
Installation Type Project-specific structural assembly
Drawing Reference Approved engineering drawings
Dimensions Customized according to project requirements
Structural Material Selection
Material Option Typical Application
Carbon Steel General industrial structural support
Stainless Steel Projects requiring specified corrosion resistance
Galvanized Steel Structural components requiring a galvanized surface finish

Material grades, section sizes, surface treatment and connection details are subject to the approved project specifications. Final selection should consider the operating environment and structural design requirements.

3. Application & Compliance
Refinery Air Cooler Installation

In refinery cooling systems, air-cooled heat exchangers are commonly installed on elevated steel structures to accommodate equipment layout and maintenance access requirements.

The installation drawing provides the arrangement of supporting members, equipment platforms and access structures. It helps EPC contractors and installation teams coordinate steel structure erection, equipment positioning and maintenance access.

For projects involving forced-draft or induced-draft air coolers, the structural arrangement must be coordinated with the actual equipment configuration and approved engineering documents.

4. Standards & Engineering Requirements

API Standard 661:2013 (7th Edition, reaffirmed July 2024) provides requirements and recommendations for air-cooled heat exchanger design, materials, fabrication, inspection, testing and preparation for shipment.

The installation drawing is developed with reference to the applicable project requirements.

API 661 compliance of the complete equipment does not automatically mean that every individual structural drawing is separately certified.

Applicable structural design codes, welding requirements and inspection criteria should be confirmed in the project specification.

5. Procurement & Project Information
Commercial Item Supply Arrangement
MOQ Quotation based on project scope; 1 set can be discussed
Price Negotiable, according to drawing and fabrication scope
FOB FOB Ningbo, China, or other agreed Incoterms
Lead Time Confirmed after technical review and order approval
Documentation Drawing package and inspection documents as agreed
6. Frequently Asked Questions
Q1: What information is required to prepare an air cooler installation drawing?

Please provide the equipment GA drawing, overall dimensions, support loads, foundation information and applicable project specifications.

Q2: Can the steel structure be customized for an existing air cooler?

Yes. The existing equipment dimensions, support positions and interface requirements can be reviewed for a project-specific structural arrangement.

Q3: Does API 661 cover the entire steel structure installation drawing?

API 661 addresses air-cooled heat exchanger design and related requirements. Detailed structural engineering and installation documentation must also follow the applicable project specifications and structural codes.

Request a Project-Based Quotation

Looking for an API 661 air cooler installation drawing, steel support structure or complete air-cooled heat exchanger solution? Contact YUHONG GROUP CO., LTD. with your equipment drawings, technical specifications and project requirements.

Our engineering and sales teams can review your requirements and provide a technical proposal and quotation.

Send us your drawings today to discuss your project.

API 661 air cooler steel structure installation drawing showing supporting columns, main beams, cross members, diagonal bracing, platforms, walkways, handrails and ladders for a refinery air-cooled heat exchanger project
Related Products
Send An Inquiry