Custom Type Fixed Tubesheet Shell and Tube Heat Exchanger for Inter Cooler
Productdetails
| Beugel: | A516 GR.60 | Buismateriaal: | C70600 O61 |
|---|---|---|---|
| Thermisch ontwerp: | HTRI-software berekend | Thermische prestaties: | Hoog warmteoverdrachtsysteem |
| Bedrijfstemperatuur: | 150-40°C | Smeedstukken: | SA-350-LF3, SA-350-LF1 of LF2 |
| Seismische belasting: | UBC-1994 | Ontwerptypen: | Vaste buizenplaat, zwevende kop, buis |
| Handvat: | SA387 GR.11 CL2 | Buizen: | SA336F12 |
| Afdichtingsstrips: | SS316L | Product: | Warmtewisselaar |
| Uitbreidingsverbinding: | Balgtype optioneel | Torisphericalhoofd: | SA-516 Gr.70N |
Productomschrijving
Custom Type Fixed Tubesheet Shell and Tube Heat Exchanger for Inter Coole
1. Equipment Overview & Configuration
A fixed tubesheet design (typically TEMA Type AEL or BEM) represents the most robust and leak-proof configuration for compressor intercooler applications. Because the tubesheets are welded directly to the shell, there are no internal gaskets or floating mechanisms, completely eliminating potential bypass leakage between high-pressure process gas and the cooling medium.
2. Comprehensive Technical Data Sheet (Mechanical & Thermal
The table below outlines a standard custom configuration for a high-pressure stage intercooler.
| Parameter Category | Specification Details: Shell Side | Specification Details: Tube Side |
| Fluid Allocation | Cooling Medium (e.g., Water / Glycol) | Process Gas (e.g., Air, Methanol Gas, N₂/H₂) |
| TEMA Type Components | E (One-Pass Shell) / M (Fixed Tubesheet) | A (Removable Channel & Cover) / L (Bonnet) |
| Design Pressure | 1.0 MPa (145 psi) [Customizable] | 3.5 MPa (508 psi) [Customizable] |
| Design / Test Temperature | -10°C to 80°C | -10°C to 180°C |
| Operating Temperature | Inlet: 25°C $rightarrow$ Outlet: 38°C | Inlet: 150°C $rightarrow$ Outlet: 40°C |
| Corrosion Allowance | 1.5 mm | 3.0 mm (or based on gas corrosivity) |
| Pass Count | 1-Pass | 2-Pass or 4-Pass (Optimized for gas velocity) |
| Joint Type | N/A | Strength Welded + Extended Expanded |
3. Material Selection Matrix (Custom Options)
Materials are selected based on the specific chemistry of the process gas and the quality of the cooling water.
| Component | Standard Industrial Carbon Steel | Premium High-Corrosion / Duplex Options |
| Shell & Shell Cover | ASME SA516 Gr. 70 | ASME SA240 Type 304 / 316L Stainless Steel |
| Tubesheet | ASME SA105 / SA516 Gr. 70 | ASME SA240 S31803 (Duplex) / SS316L Clad |
| Heat Exchanger Tubes | ASME SA179 (Cold Drawn Carbon Steel) | ASME SA213 TP316L / SA789 S31803 (Duplex) |
| Tube Profile | Bare / Smooth Tube | Low-Finned (Integral) / Corrugated Tubes |
| Baffles & Spacers | ASME SA283 Gr. C / SS304 | SS316L |
| Channel / Bonnet | ASME SA106 Gr. B / SA516 Gr. 70 | ASME SA240 TP316L |
4.Typical Industrial Sector Applications
This specific ASME/NBR certificated design is built for heavy industrial environments, including:
Oil & Gas Refineries: Inter-stage cooling of hydrocarbon gases, recycle hydrogen gas, and sour gases.
Petrochemical & Methanol Plants: Cooling of synthesis gas (Syngas) and high-pressure process loops.
Air Separation Units (ASU): Multi-stage centrifugal air compressors producing bulk O2 and N2.
Large-scale Utilities: High-pressure plant air systems where NBR/NR-13 compliance is mandatory for South American/Brazilian operations.

Producthoogtepunten
Custom Type Fixed Tubesheet Shell and Tube Heat Exchanger for Inter Coole 1. Equipment Overview & Configuration A fixed tubesheet design (typically TEMA Type AEL or BEM) represents the most robust and leak-proof configuration for compressor intercooler applications. Because the tubesheets are welded ...
Plug Type Industriële Luchtgekoelde Warmtewisselaar Petrochemische en Olie Raffinaderijen Toepassing
Luchtkoeler volgens API 661 en ASME SEC VIII Div-1, Petrochemische en Olie Raffinaderij Toepassing Voordelen van Luchtkoelers in Olie Raffinaderijen: Waterbesparing: In tegenstelling tot watergekoelde systemen hebben luchtkoelers geen grote hoeveelheden water nodig. Kosteneffectief: Lagere ...
Custom Type Fixed Tubesheet Shell and Tube Heat Exchanger for Inter Cooler
Custom Type Fixed Tubesheet Shell and Tube Heat Exchanger for Inter Coole 1. Equipment Overview & Configuration A fixed tubesheet design (typically TEMA Type AEL or BEM) represents the most robust and leak-proof configuration for compressor intercooler applications. Because the tubesheets are welded ...
ASME SB171 C46400 Marine Messing Tubesheet
ASME SB171 C46400 Marine messing buizenplaat | Zeewater corrosiebestendig voor warmtewisselaarcondensor ASME SB171 C46400-buisplaten zijn drukdragende kerncomponenten in shell-and-tube-warmtewisselaars, condensors en drukvaten, die worden gebruikt om de buizenbundel vast te zetten en af te dichten ...
ASME SB171 C61400 aluminium bronzen schijf met weerstand tegen zeewatererosie en nauwkeurig bewerkte afwerking
ASME SB171 C61400 aluminium bronzen schijf | Machinaal gesmeed rond blanco Metabeschrijving:Zwaar uitgevoerde ASME SB171 C61400 aluminiumbronzen schijven, op maat gedraaid voor buizenplaten van warmtewisselaars, maritieme botsingsplaten en offshore-flenzen. Uitstekende weerstand tegen erosie van ...
Gebruik ons online contactformulier als u vragen heeft, ons team zal u zo snel mogelijk contacteren.