Latest company news about Air-Cooled Heat Exchanger K Values: Complete Data for Air Coolers and Air-Cooled Condensers

November 18, 2026

Air-Cooled Heat Exchanger K Values: Complete Data for Air Coolers and Air-Cooled Condensers

News Details

By the Yuhong Group technical team

Overview

Air coolers and air-cooled condensers use ambient air as the cooling medium. Because air has a very low density and thermal conductivity, the convective heat transfer coefficient on the air side is extremely low. To compensate, finned tubes are used to multiply the effective surface area by 10 to 20 times. At Yuhong Group, we specialize in supplying high-frequency welded finned tubes that ensure a metallurgical bond, eliminating contact resistance and maximizing K values.

15. Air Coolers
Cooling Material Coolant Material K Value [W/(m²·K)] Remarks
Low carbon hydrocarbons Air
436~552 Horizontal finned tube air cooler
Light oil Air
349~407 Horizontal finned tube air cooler
Light petroleum Air
407 Horizontal finned tube air cooler
Fuel oil Air
116~174 Horizontal finned tube air cooler
Residual oil Air
58~116 Horizontal finned tube air cooler
Coke oil Air
29~58 Horizontal finned tube air cooler
Flue gas Air
58~174 Horizontal finned tube air cooler
Hydrogen reactor gas Air
465~523 Horizontal finned tube air cooler
Hydrocarbon gas Air
174~523 Horizontal finned tube air cooler
Air or fuel gas Air
58 Horizontal finned tube air cooler
Machine cooling water Air
709 Horizontal finned tube air cooler
16. Air Condensers
Condensing Material Coolant Material K Value [W/(m²·K)] Remarks
Low boiling point hydrocarbons Air
453~535 Horizontal finned tube air cooler
Amine reactor steam Air
511~569 Horizontal finned tube air cooler
Ammonia vapor Air
569~686 Horizontal finned tube air cooler
Freon vapor Air
337~453 Horizontal finned tube air cooler
Light gasoline vapor Air
453 Horizontal finned tube air cooler
Light naphtha vapor Air
395~453 Horizontal finned tube air cooler
Tower top gas (light naphtha steam and non-condensables) Air
337~453 Horizontal finned tube air cooler
Heavy naphtha vapor Air
337~453 Horizontal finned tube air cooler
Low pressure steam Air
767 Horizontal finned tube air cooler
Heavy virgin oil Air
395 Horizontal finned tube air cooler
Yuhong Group Supply & CTA

Maximize your air cooler's K value with premium finned tubes. At Yuhong Group, we manufacture high-frequency welded finned tubes, extruded finned tubes, and seamless base pipes with strict quality control. We offer a flexible MOQ (1 Ton), competitive FOB pricing, and a reliable Lead Time (15-25 days). Contact our technical team today for material consultation and a fast quotation.

Frequently Asked Questions
What K values can an air cooler achieve?

Based on bare tube area: 436 to 552 W/(m²·K) for light hydrocarbons, 349 to 407 W/(m²·K) for light oil, and only 29 to 58 W/(m²·K) for coke oil.

How do air condenser K values compare?

Ammonia vapour condensing against air gives 569 to 686 W/(m²·K), low pressure steam 767 W/(m²·K), and light gasoline vapour 453 W/(m²·K).

Why do fins matter so much in air coolers?

The air-side coefficient is the controlling resistance, so fins multiply the effective surface area by 10 to 20 times. A high-frequency welded metallurgical bond keeps that area working year after year.