Air Cooler Tube Bundle | 304L, 2205 & Nickel Alloy Base Tubes
An air cooler tube bundle is the heat transfer core of an air-cooled heat exchanger (fin fan cooler): process fluid flows inside the tubes while ambient air is driven across the finned outside surface. YUHONG GROUP builds replacement and new-build bundles to the approved drawing, with tube grade, fin geometry, header type and tube sheet selected against the process fluid, design pressure and site atmosphere.
Product Overview
Each assembly combines finned tubes, two headers, drilled tube sheets and a structural side frame. The tube side forms the pressure boundary; the air side is extended by aluminium fins because air has a low heat transfer coefficient. Design and fabrication follow API 661 for refinery air-cooled heat exchangers and ASME Section VIII Division 1 for pressure-containing header boxes, with ASME U-stamp and PED documentation available where the order requires it.
Replacement air cooler tube bundles are duplicated from the original bundle drawing or measured from the withdrawn bundle, so tube count, row layout, tube pitch, fin density, header arrangement and nozzle orientation match the existing frame and piping.
Materials and Configuration
Base Tubes
Primary material options cover austenitic stainless steel (TP304L, TP316L, TP321), duplex S32205 / 2205, nickel alloy (ASME SB163 N04400 / Alloy 400) and copper-nickel (C70600 90/10, C71500 70/30). Carbon steel SA179 / SA106 Gr.B and low-alloy P9 / P11 / P22 remain available as alternative base tubes for non-corrosive hydrocarbon service.
Selection follows the duty: 316L or 2205 for chloride-bearing service and coastal atmospheres, N04400 for seawater-side and reducing-acid service, and stainless or duplex where iron pickup in the condensate is not acceptable. Wall thickness is fixed by design pressure, not by a stock size.
Fin Types and Temperature Limits
Fin geometry is set by metal temperature as well as heat duty:
- Extruded (bimetallic) fin — aluminium outer fin formed over the base tube; published service range up to ~300 °C.
- Embedded G-fin — aluminium strip wound into a 0.25–0.30 mm helical groove and locked by back-filled tube metal; published service range up to ~400 °C. The groove removes tube wall, so the base wall thickness is increased to hold the pressure rating.
- Wrapped L / KL / LL fin — tension-wound fin foot; published service range ~130–180 °C.
Typical published fin geometry: base tube OD 15.88–50.80 mm, fin height 6.35–15.88 mm, fin thickness 0.20–0.50 mm, fin pitch 5–11 FPI, aluminium 1050 / 1060 fins.
For the embedded type, fin retention is mechanical and measurable: fin pull-off force is specified at ≥70 N on published G-type builds, and SA179 base tubes are heat treated at ≥650 °C after the final cold-draw pass with hardness held to ≤72 HRB. These are the inputs that govern fin-to-tube contact under thermal cycling; no performance multiplier is assumed.
Headers, Tube Sheets and Frame
Header options include the plug header (a removable plug opposite each tube for inspection and mechanical cleaning on high-pressure service), the cover plate header (full access to the tube sheet where fouling is expected), the manifold / pipe header for elevated temperature and pressure, and U-tube bundles that absorb differential thermal expansion without loading the tube sheet joint.
Tube sheets are supplied in SA516 Gr.70, SA240 304/316L, forged SA105, SA182 F316L or SA336, with weld overlay or cladding when the tube-side fluid calls for it. Side frames use galvanised carbon steel structural channels; coated or stainless frames are specified for coastal sites.
Technical Parameters at a Glance
|
Parameter
|
Published configuration
|
|
Base tube OD
|
15.88 – 50.80 mm
|
|
Base tube wall
|
From 1.65 mm; sized to design pressure and fin groove depth
|
|
Tube materials
|
TP304L / TP316L / TP321, S32205 (2205), SB163 N04400, C70600 / C71500; SA179, SA106 Gr.B, P9 / P11 / P22 as alternatives
|
|
Fin material
|
Aluminium 1050 / 1060
|
|
Fin height
|
6.35 – 15.88 mm
|
|
Fin thickness
|
0.20 – 0.50 mm
|
|
Fin pitch
|
5 – 11 FPI
|
|
Fin types
|
Extruded, embedded G, wrapped L / KL / LL
|
|
Service temperature by fin
|
L / KL / LL ~130–180 °C; G ~400 °C; extruded ~300 °C
|
|
Header types
|
Plug, cover plate, manifold / pipe, U-tube
|
|
Tube sheet
|
SA516 Gr.70, SA240 304/316L, SA105, SA182 F316L, SA336
|
|
Design codes
|
API 661, ASME Section VIII Div. 1
|
|
Documentation
|
MTC, hydrostatic test report, dimensional report; PMI and third-party inspection on request
|
Quality Control and Documentation
Every bundle is hydrostatically tested to the design pressure before shipment. The documentation set covers material test certificates for tubes, fins and headers, the hydrostatic test report, and a dimensional inspection report confirming fit to the existing frame. PMI and third-party inspection (SGS, BV, TÜV) can be added at the buyer's request.
Typical Applications
- Refinery and petrochemical overhead condensation and reactor effluent cooling
- Natural gas and compressor aftercooling, gas plant intermediate cooling
- Power generation lube oil and generator cooling
- Offshore and coastal installations, where chloride exposure drives 316L, 2205 or N04400 selection
How to Specify a Replacement Air Cooler Tube Bundle
Send these inputs so the replacement matches the installed frame:
- Original bundle drawing, or the withdrawn bundle for measurement
2.Tube count, number of rows, tube pitch, tube length and overall bundle dimensions
3. Base tube grade and wall thickness; fin type, fin height, fin pitch and fin material
4. Header type, nozzle size and nozzle orientation
5. Process fluid, design pressure, design temperature and required cooling duty
6. Required code stamping and inspection / documentation package
Fin density and fin type are the two common sources of mismatch. Too few fins reduce air-side surface area; too many restrict airflow; substituting a wrapped fin for an extruded fin changes both the temperature limit and the fin-to-tube bond.
FAQ
Can the tube bundle be replaced without changing the fan frame? Yes. Replacement bundles are built to the original drawing so tube count, layout, header arrangement and interface dimensions match the existing structure and piping.
Which fin type is specified for high metal temperatures? Embedded G-fin (~400 °C published limit) or extruded fin (~300 °C). Wrapped L / KL / LL fins are limited to ~130–180 °C. For G-fins, the 0.25–0.30 mm groove requires a thicker base tube to maintain the pressure rating.
Send the bundle drawing and service conditions for dimensional confirmation and a technical proposal.